top of page

lawyers.ca duimetrology.com
905-273-3322 or 1-877-273-3322
Search


Stephen Biss
Jan 13, 20234 min read
Reliability: Flooded Sample Chamber 2
Unfortunately it is very easy for a qualified technician to reverse the inlet and outlet couplings Intoxilyzer to wet-bath simulator.
14 views0 comments
Stephen Biss
Jan 4, 20233 min read
Reliability: Flooded Sample Chamber 1
It is very easy for a qualified technician to accidentally flood the sample chamber on an Intoxilyzer 5000 (or 5000C) or an 8000 (or...
11 views0 comments
Stephen Biss
Dec 28, 20222 min read
Reliability: Aging - Losing Memory
The Intoxilyzer® 8000 depicted in this video was once a reliable evidentiary breath testing instrument in the United States. It is...
12 views0 comments


Stephen Biss
Dec 21, 20227 min read
Continuity of Alcohol Standard Solution: Keep from Freezing
Many years ago I asked for timely disclosure/production of a representative bottle of the alcohol standard lot used during the breath...
62 views0 comments
Stephen Biss
Dec 14, 20221 min read
What is SCC: R. v. St-Onge Lamoureux "Reliability" in an Approved Intrument?
Please carefully re-read what the Supreme Court of Canada said about "reliability" in R. v. St-Onge Lamoureux. Please think about and...
13 views0 comments


Stephen Biss
Dec 8, 20226 min read
What is Differential Voltage Monitoring (DVM) ?
Many years ago Ontario defence lawyers cross-examined breath techs on "how much room there was" on the particular Intoxilyzer 5000C to...
9 views0 comments


Stephen Biss
Nov 30, 20228 min read
Reliability: Ambient Conditions
Tip 41: Changing breath room ambient conditions can reduce "system calibration check" and "system blank test" reliability. Any...
29 views0 comments


Stephen Biss
Nov 23, 20224 min read
Ancient Egypt and DUI Metrology
If you served wine or beer at a pub in ancient Egypt the beverages were measured out using liquid volume instruments like these. Each...
10 views0 comments


Stephen Biss
Nov 17, 20223 min read
Study the Block Diagram in the Wet-Bath Simulator Manufacturer's Manual
Tip 25: Obtain a copy of the Guth Laboratories, Inc. wet-bath "Model 2100 Simulator Operation Manual" and study the "Model 2100-Block...
14 views0 comments


Stephen Biss
Oct 19, 20227 min read
Error in Facts - "Impaired Driving and Other Criminal Code Driving Offences", Jokinen and Keen
Does partial automation of error-checking in an approved instrument: specifically diagnostics tests, air blanks, cal. checks, and maximum...
27 views0 comments


Stephen Biss
Oct 15, 20224 min read
Continuity: From the Box
Tip 37: Defence lawyers need to study the video - does the qualified technician take a random (unrelated to the matter before the Court)...
13 views0 comments

Stephen Biss
Oct 12, 20224 min read
Change of Response at One Point but Not at Another Point that is Equivalent
Purpose: To suggest that there is empirical evidence in the matter before the Court of change in response by the approved instrument at...
18 views0 comments


Stephen Biss
Oct 6, 20221 min read
Certificate of Calibration of a NIST mercury thermometer
Tip 14: Whenever police purchase a new NIST mercury thermometer, the Canadian distributor provides them with a "Guth Laboratories, Inc....
16 views0 comments


Stephen Biss
Oct 3, 20222 min read
Continuity: Use of a Seal
Tip 38: One of the best ways to control wet-bath simulator alcohol standard continuity is to use alphanumeric police seals and record...
12 views0 comments


Stephen Biss
Sep 30, 20221 min read
Continuity: Whiteboard or blackboard method
Tip 36: Some police detachments have been known to write the manufacturer name, lot number, name/badge of solution change officer,...
21 views0 comments
Stephen Biss
Sep 26, 20222 min read
What is Purge Fail on an Intoxilyzer ?
What is a Purge Fail on an Intoxilyzer 8000C ? What is a Purge File on an Intoxilyzer 5000C ? How does this phenomenon affect reliability...
34 views0 comments
Stephen Biss
Sep 13, 20221 min read
What is an Ambient Fail on an Intoxilyzer 8000C?
What does "ambient fail" or "ambient failed" mean on an Intoxilyzer 8000C? Watch the following video and ask yourself why the ambient...
68 views0 comments
Stephen Biss
Sep 12, 20222 min read
What is an air blank on an Intoxilyzer 8000C?
What does an air blank look like on an Intoxilyzer 8000 or 8000C? What is a blank test? What is a system blank test? What does 000 mean...
38 views0 comments


Stephen Biss
Sep 9, 20221 min read
Anecdotal Notes in Alcohol Standard Log
Tip 29: Obtain disclosure, of the full #duisimulator alcohol standard log, to search for anecdotal notes of difficulties experienced by...
13 views0 comments


Stephen Biss
Sep 4, 20223 min read
Reliability: 64 in 2011 Ambient Threshold Changes, Elevated Zero, Purge Fail
This is the same Intoxilyzer® 64 with upgraded keyboard and (software) serial number depicted in the blog "Ambient Conditions Change...
11 views0 comments
bottom of page