Floating zero (in the context of the Intoxilyzer)

On an approved instrument that uses infrared (IR) spectroscopy as a measurement system, there is no true zero. The instrument reads a number between about 0 and 600 (e.g. 300) coming off its circuitry (on the Intoxilyzer 5000C this was called the DVM) and subtracts the DVM value of maybe "190" (where it thinks zero is) to produce a final result of 110. The 190 value is actually constantly changing depending on the stability of the electronics and the cleanliness of the sample chamber. An instrument that is badly in need of maintenance may have its DVM fluctuating wildly, thus sometimes triggering a diagnostics fail (processor error, processer positive or negative drift). On a properly operating instrument the zero is reset whenever there is an ambient air blank test. In other words, on a properly operating machine (or an improperly operating machine), if room air is compromised then zero is compromised, and the air blanks (checking for excessive ambient alcohol), the cal. checks, and the subject tests are all compromised. Since zero is always changing, even on a properly operating machine, with minimal ambient alcohol, there will be variability in the indicated results.

Zero floats up and down on infrared measuring instrument depending on ambient conditions

If you are a member of the public, please don't attempt to use what you see or read at this site in Court. It is not evidence. The author is not a scientist. The author has a great deal of experience in cross-examining scientists about these issues, but the author is not a scientist. Hire a criminal lawyer in private practice in Ontario. Your lawyer can retain an expert. The author is a retired lawyer, not a lawyer in private practice. Read the statement of the purpose of this web site below.

© 2025 Allbiss Lawdata Ltd.

This site has been built by Allbiss Lawdata Ltd. All rights reserved. This is not a government web site.

For more information respecting this database or to report misuse contact: Allbiss Lawdata Ltd., Mississauga, Ontario, Canada, 905-273-3322. The author and the participants make no representation or warranty  whatsoever as to the authenticity and reliability of the information contained herein.  WARNING: All information contained herein is provided  for the purpose of discussion and peer review only and should not be construed as formal legal advice. The authors disclaim any and all liability resulting from reliance upon such information. You are strongly encouraged to seek professional legal advice before relying upon any of the information contained herein. Legal advice should be sought directly from a properly retained lawyer or attorney. 

WARNING: Please do not attempt to use any text, image, or video that you see on this site in Court. These comments, images, and videos are NOT EVIDENCE. The Courts will need to hear evidence from a properly qualified expert. The author is not a scientist. The author is not an expert. These pages exist to promote discussion among defence lawyers.

Intoxilyzer®  is a registered trademark of CMI, Inc. The Intoxilyzer® 5000C is an "approved instrument" in Canada.

Breathalyzer® is a registered trademark of Draeger Safety, Inc., Breathalyzer Division. The owner of the trademark is Robert F. Borkenstein and Draeger Safety, Inc. has leased the exclusive rights of use from him. The Breathalyzer® 900 and Breathalyzer® 900A were "approved instruments" in Canada.