Control test (in the context of the Intoxilyzer)

Since the evidentiary instrument is, at best, only re-calibrated at the Canadian Authorized Service Centre once per year, police, or a scientist running any measurement, needs a rough, in the field, method of checking calibration, at least at some middle value, close to the expected range of results. With wet bath alcohol standard, the contents of the head space (the air) above the liquid in the simulator (that came from the bottle that came from the lab) are pumped through the Intoxilyzer sample chamber to see how well the Intoxilyzer analyzes a "known" sample. For example, if the Intoxilyzer reads a 100 wet bath solution as 97 or 104, then the Intoxilyzer seems to be working within a few mg% if the subject is close to 100 mg%. The wet bath simulator is used to test the Intoxilyzer, not the other way around. You can't use the Intoxilyzer to check the simulator/alcohol standard system. The simulator/alcohol standard system must always be a "known". The Intoxilyzer is the "unknown". Alternatively you can pump dry gas/air gas into an Intoxilyzer 8000C or other approved instrument to do the same kind of control test. If you use a wet bath system you use liquid alcohol standard. If you use dry gas you buy a canister of dry gas in a round cylinder that attaches to the back of the approved instrument. If you use wet bath the alcohol standard liquid/headspace/simulator system needs to be carefully kept at 34 plus or minus .2 degrees Celsius. If you use dry gas, there is no temperature issue, but there is an ambient atmospheric pressure issue.

A "control" in an experiment is constant and unchanged throughout the course of the investigation. It is kept the same throughout the experiment. If the control changes, the experiment is biased. If the vapour coming from the wet-bath simulator is not at the correct temperature specified on the bottle of alcohol standard, then there is no "control". If the Intoxilyzer pump is not working properly or there is a leak in the simulator re-circulating system then there is no "control". See Henry's Law.

Sealed container at known temperature with liquid below and gas above necessary for Henry's Law - wet-bath simulator and alcohol standard used as a control.
Blog entries on "control test"

If you are a member of the public, please don't attempt to use what you see or read at this site in Court. It is not evidence. The author is not a scientist. The author has a great deal of experience in cross-examining scientists about these issues, but the author is not a scientist. Hire a criminal lawyer in private practice in Ontario. Your lawyer can retain an expert. The author is a retired lawyer, not a lawyer in private practice. Read the statement of the purpose of this web site below.

© 2025 Allbiss Lawdata Ltd.

This site has been built by Allbiss Lawdata Ltd. All rights reserved. This is not a government web site.

For more information respecting this database or to report misuse contact: Allbiss Lawdata Ltd., Mississauga, Ontario, Canada, 905-273-3322. The author and the participants make no representation or warranty  whatsoever as to the authenticity and reliability of the information contained herein.  WARNING: All information contained herein is provided  for the purpose of discussion and peer review only and should not be construed as formal legal advice. The authors disclaim any and all liability resulting from reliance upon such information. You are strongly encouraged to seek professional legal advice before relying upon any of the information contained herein. Legal advice should be sought directly from a properly retained lawyer or attorney. 

WARNING: Please do not attempt to use any text, image, or video that you see on this site in Court. These comments, images, and videos are NOT EVIDENCE. The Courts will need to hear evidence from a properly qualified expert. The author is not a scientist. The author is not an expert. These pages exist to promote discussion among defence lawyers.

Intoxilyzer®  is a registered trademark of CMI, Inc. The Intoxilyzer® 5000C is an "approved instrument" in Canada.

Breathalyzer® is a registered trademark of Draeger Safety, Inc., Breathalyzer Division. The owner of the trademark is Robert F. Borkenstein and Draeger Safety, Inc. has leased the exclusive rights of use from him. The Breathalyzer® 900 and Breathalyzer® 900A were "approved instruments" in Canada.

Alcotest® is a registered trademark of Draeger Safety, Inc. The Alcotest® 7410 GLC and 6810 are each an "approved screening device" in Canada.

Datamaster®  is a registered trademark of National Patent Analytical Systems, Inc.  The BAC Datamaster® C  is an "approved instrument" in Canada.

bottom of page